Need a new Water Heater
Me ^ | 4/29/19 | Me

Posted on 04/29/2019 12:56:12 PM PDT by ProtectOurFreedom

Does anybody have experience with "Power Direct Vent" water heaters? I need to replace our conventional natural draft water heater and am thinking about a Power Direct Vent model. These units have a sealed combustion chamber and take outside air via a PVC pipe for combustion and the send the combustion gases outdoors via another PVC pipe.

I've read that the fans and burners on PDV water heaters can make a lot of objectionable noise. The fans make noise especially when starting up and the burners can make a loud rumbling noise.

Our forced air furnace is a similar design with a sealed combustion chamber and the coaxial pipe for air inlet / flue gas discharge. I don't hear the exhaust fan or burner rumble noise from the furnace.

I need to switch to a sealed combustion water heater as part of an energy retrofit program to prevent future ice dams in the winter. We had terrible ice dams this winter (North Idaho, Climate Zone 5) leading to water getting into the walls and buckling a small part of our newly refinished floor (nothing hurts like seeing your beautiful newly refinished floor buckling!)

In looking into the problem, I've found a lot of root causes for the ice dams - inadequate attic insulation (bare ceiling sheet rock in places!), inadequate attic ventilation, no air sealing between the house and the attic, and a utility room dumping a lot of warm air into the attic which melts roof snow.

The existing water heater in the utility room is installed per code and has two combustion (fresh) air inlets, one in the ceiling (communicates to the attic for air) and one in the floor (communicates to the crawl space for air). This creates a perfect convection path where cold crawl space air enters the utility room, is heated to 50F to 70F, and then flows into the attic where the warm air melts the snow leading to the ice dams. By switching to a Power Direct Vent water heater, I can close off the floor and ceiling vents and stop all the heat in the utility / mechanical room from flowing into the attic.

But these Power Direct Vent water heaters are expensive and I'm concerned about the possible noise problems.

The energy savings will never pay for this upgrade, but it's really important to stop the ice dam problem.


TOPICS: Miscellaneous
KEYWORDS: idaho; qanon; waterheater
Navigation: use the links below to view more comments.
first 1-2021-4041-6061-8081-98 next last
Anybody have experience with these "Power Direct Vent" water heaters?
1 posted on 04/29/2019 12:56:12 PM PDT by ProtectOurFreedom
[ Post Reply | Private Reply | View Replies]

To: ProtectOurFreedom
This creates a perfect convection path where cold crawl space air enters the utility room, is heated to 50F to 70F, and then flows into the attic where the warm air melts the snow leading to the ice dams

You are buying a new water heater because of that? Reroute the pipes, install a fan, ventilate the attic, install attic floor insulation, etc. All of those things are cheaoer and have better payback.

2 posted on 04/29/2019 1:00:57 PM PDT by palmer (...if we do not have strong families and strong values, then we will be weak and we will not survive)
[ Post Reply | Private Reply | To 1 | View Replies]

To: ProtectOurFreedom

I have a “tankless” heater than runs on LNG and I love it. Never run out of hot water and faiy cheap (in PA) to run.


3 posted on 04/29/2019 1:01:14 PM PDT by airborne (I don't always scream at the TV but when I do it's hockey season!)
[ Post Reply | Private Reply | To 1 | View Replies]

To: ProtectOurFreedom

If it were me, I’d look into one of those on-demand, tankless, endless hot water heaters.


4 posted on 04/29/2019 1:02:04 PM PDT by AnalogReigns
[ Post Reply | Private Reply | To 1 | View Replies]

To: ProtectOurFreedom

PVC for intake and exhaust gases?...................


5 posted on 04/29/2019 1:02:12 PM PDT by Red Badger (We are headed for a Civil War. It won't be nice like the last one....................)
[ Post Reply | Private Reply | To 1 | View Replies]

To: ProtectOurFreedom

I don’t know anything about this brand.

What I do know is that water heaters can go bad and leak and can flood the house, so it is best to put them outside, not inside the house.

One of the first things I did when I bought my house was to move the water heater outside.


6 posted on 04/29/2019 1:02:14 PM PDT by Innovative
[ Post Reply | Private Reply | To 1 | View Replies]

To: ProtectOurFreedom

I’ve had one for fourteen years. Natural gas fuel. EFFICIENT. Has needed no repairs and is still going strong. The cost over a standard gas hot water heater, as I recall, was about 30% more, but the higher efficiency paid that premium in the first three years or so.


7 posted on 04/29/2019 1:03:46 PM PDT by the Original Dan Vik ("Men don't follow titles, they follow courage." -William Wallace in Braveheart, 1995)
[ Post Reply | Private Reply | To 1 | View Replies]

To: ProtectOurFreedom

You are talking about ventless water heaters. Yes, they work using nearly all the heat to heat the water. But gas water heaters today have very thin tanks that will only last 3-5 years. Consider getting a tankless water heater. More expensive up front but they have a much longer life.


8 posted on 04/29/2019 1:03:50 PM PDT by Blood of Tyrants (Being woke means you can be nasty, hateful and use racist slurs yet feel morally superior.)
[ Post Reply | Private Reply | To 1 | View Replies]

To: ProtectOurFreedom
In looking into the problem, I've found a lot of root causes for the ice dams - inadequate attic insulation (bare ceiling sheet rock in places!), inadequate attic ventilation, no air sealing between the house and the attic, and a utility room dumping a lot of warm air into the attic which melts roof snow.

Solution:

Move to Florida...................

9 posted on 04/29/2019 1:03:56 PM PDT by Red Badger (We are headed for a Civil War. It won't be nice like the last one....................)
[ Post Reply | Private Reply | To 1 | View Replies]

To: ProtectOurFreedom

My last WH installation was a gas-fired tankless (on demand) water heater. But I’m not familiar with DPV.

It is mounted on the inside of the outer wall of the laundry room and the exhaust vents straight through the wall from a foot-or-so long insulated pipe. Takes up very little space.

Saves gas since it heats on demand, but maybe a few seconds slower to get hot than from a tank that’s already heated.


10 posted on 04/29/2019 1:04:43 PM PDT by JimRed ( TERM LIMITS, NOW! Build the Wall Faster! TRUTH is the new HATE SPEECH.)
[ Post Reply | Private Reply | To 1 | View Replies]

To: Innovative

One of the first things I did when I bought my house was to move the water heater outside.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

You don’t live in Minnesota


11 posted on 04/29/2019 1:07:48 PM PDT by shelterguy
[ Post Reply | Private Reply | To 6 | View Replies]

To: ProtectOurFreedom

Hi.

“Power Direct Vent” water heaters?”

First let me say I’m not experienced or an expert on water heaters.

But, depending on where you live, quality of water you have to flush and drain the water heater every two or so years.

Good luck.

5.56mm


12 posted on 04/29/2019 1:07:52 PM PDT by M Kehoe (DRAIN THE SWAMP! BUILD THE WALL!)
[ Post Reply | Private Reply | To 1 | View Replies]

To: ProtectOurFreedom

If your hot water vents to the attic, consider insulating the pipes. Code calls for R-8 on duct pipes in uninsulated spaces. Not sure about for vent stacks.

I would think though, with proper air sealing and insulation, that would solve the vast majority of your problems.

If you’re thinking of doing this yourself, PM me. The company I work for makes some good products for air sealing attics and I’ve got a decent level of knowledge of the job.


13 posted on 04/29/2019 1:14:47 PM PDT by cyclotic
[ Post Reply | Private Reply | To 1 | View Replies]

To: ProtectOurFreedom

Get a tankless, I love mine.


14 posted on 04/29/2019 1:15:37 PM PDT by McGavin999 (Border security without a wall is like having a Ring doorbell without a doorw)
[ Post Reply | Private Reply | To 1 | View Replies]

To: AnalogReigns
If it were me, I’d look into one of those on-demand, tankless, endless hot water heaters.

My new Florida home has a natural gas-fired Rheem unit mounted on the outside. We love it.

15 posted on 04/29/2019 1:16:14 PM PDT by Quality_Not_Quantity (Even my cat voted Republican)
[ Post Reply | Private Reply | To 4 | View Replies]

To: ProtectOurFreedom

We got a new system that has a much smaller tank but heats the water to a much higher temperature. The very hot water mixes with cold as it exits the system. Much more efficient since far less water is kept hot. We saw good savings.


16 posted on 04/29/2019 1:19:05 PM PDT by FatherofFive (Islam is EVIL and needs to be eradicated)
[ Post Reply | Private Reply | To 1 | View Replies]

To: Red Badger

Solution:

Move to Florida...................

***********************************

But then there’s the need to invest in such very strong perimeter defenses to safeguard against wandering groups of Florida Man.


17 posted on 04/29/2019 1:19:31 PM PDT by Grimmy (equivocation is but the first step along the road to capitulation)
[ Post Reply | Private Reply | To 9 | View Replies]

To: Innovative
One of the first things I did when I bought my house was to move the water heater outside.
You obviously don't live in western NY.
18 posted on 04/29/2019 1:21:44 PM PDT by oh8eleven (RVN '67-'68)
[ Post Reply | Private Reply | To 6 | View Replies]

To: ProtectOurFreedom
Go w/ Ruud or Rheem Tankless WHs.

They require stainless steel exhaust outside vents, and aren't cheap going in, but mine paid back in 5yrs, and the previous one I had at my nursery for the office bathroom, in 1990, worked for 22 yrs.

I saw it on "This Old House", spent weeks getting one of the very first models, from Oregon. and it worked beautifully. The new systems are amazing.

19 posted on 04/29/2019 1:23:32 PM PDT by Carriage Hill (A society grows great when old men plant trees, in whose shade they know they will never sit.)
[ Post Reply | Private Reply | To 1 | View Replies]

To: ProtectOurFreedom
I find it very hard to believe that you have an open vent from your water heater utility room directly into the attic space for ventilation and that meets code. It is a perfect fire path to set your whole house on fire if there is ever a fire in the utility room.

Ditto the vent to the crawl space, although fire doesn't normally go down as quickly as it goes up.

There should be a makeup air vent from the outside to a dampered box near the water heater. It allows air to come in, but doesn't let (much) air out, so it's not blowing your expensive heated air to the outdoors.

Block off the attic vent, keep the crawl space vent, and replace your water heater with another conventional gas 40 (I have a 50) gallon water heater and call it a day.

The power direct vent types have a much cooler flue gas, which requires the fan to push the exhaust out of the house. They're fine for new construction, and are more efficient, but are much more expensive to buy and can be MUCH more expensive to retrofit. Spend the money on more attic insulation instead. That will pay for itself year round if you both cool and heat your home.

Also, look for bathroom ceiling vents that blow directly into your attic. Those should also vent to the outside, but older homes just had them blow into the attic, which can also be a source of warm air that causes ice dams.

20 posted on 04/29/2019 1:23:52 PM PDT by Yo-Yo ( is the /sarc tag really necessary?)
[ Post Reply | Private Reply | To 1 | View Replies]


Navigation: use the links below to view more comments.
first 1-2021-4041-6061-8081-98 next last

Disclaimer: Opinions posted on Free Republic are those of the individual posters and do not necessarily represent the opinion of Free Republic or its management. All materials posted herein are protected by copyright law and the exemption for fair use of copyrighted works.

Free Republic
Browse · Search
General/Chat
Topics · Post Article

FreeRepublic, LLC, PO BOX 9771, FRESNO, CA 93794
FreeRepublic.com is powered by software copyright 2000-2008 John Robinson