“Try to start the shower right after the pump has cycled and I could shower for 15 minutes.”
How many gallons is your pressure tank?
Overall this seems just strange...
At the most a fully ‘open’ showerhead should deliver no more than 5 GPM. If you are depleting your stored water reservoir in a few minutes your well pump is NOT working as designed (unless it’s a 2 GPM pump).
In the last 24 years I’m on my third pressure tank (50 gallons) an third well pump (I do a lot of irrigating).
Have never had the issue you mention unless the pump was going out.
How many gallons is your pressure “tank?
Overall this seems just strange...
At the most a fully ‘open’ showerhead should deliver no more than 5 GPM. If you are depleting your stored water reservoir in a few minutes your well pump is NOT working as designed (unless it’s a 2 GPM pump).
In the last 24 years I’m on my third pressure tank (50 gallons) an third well pump (I do a lot of irrigating).
Have never had the issue you mention unless the pump was going out.”
My Pressure Tank is 30 gallons. My Pump is fine - I can get plenty of Flow and Pressure if the Oump is running. I desire is to minimize Pump running and fully utilize the Pressure Tank reserve by slowing the drawdown of the tank pressure.