To: The_Media_never_lie
Reply to The_Media_Never_Lie Powerline arcs are detectable (see below) Detection of Arc in the Transmission Power Lines Article · August 2012 with  P. Kostyla Wroclaw University of Science and Technology Abstract One- and three-phase automatic reclosing of power lines, after short circuit shutdown, is a very effective way to improve the reliability of power delivery. Re-closing while the fault is not cleared can be dangerous for some electrical appliances. This paper provides a description of two optimization methods concerning the detection of arc in the transmission power lines. The first method is based on least squares approach (LS) and second on total least squares approach (TLS). In order to identify a short-circuit arc, it is proposed to use the degree of distortion of the voltage curve at the beginning of the line, therefore the both methods are based on the estimation of parameters in real-time voltage signals and an analysis of error estimation. An artificial neural network has been proposed to solve the problem in real time. The problems are formulated as optimization tasks and solved using the steepest descent continuous-time optimization algorithm. The network based on the TLS criterion realizes the optimization process under the assumption that the signal model can also be deteriorated (frequency or sampling interval fluctuation and so forth). In comparison to LS estimation, the TLS estimation effect is more reliable when higher sampling frequency and a wider sampling window is applied. The benefit of this research is the innovative possibility of fast detection of arcing faults in real time.
19 posted on 11/13/2019 11:11:37 PM PST by WLusvardi (Drudge Fudges)
[ Post Reply | Private Reply | To 13 | View Replies ]


To: WLusvardi

When I worked as an electrical engineer at electric utilities, we had equipment that used the algorithms you mentioned. We could also look at fault waveforms and locate faults manually. At that time neither method was perfect, with either outperforming based on the situation.

Most power lines are built for moderate to extreme conditions. A transmission line can be designed for extreme wind conditions, but that gets very expensive. A power line cannot easily be retrofit for extreme conditions.

Ideally, generation should be built somewhat close to load centers. California’s environmentalists, however, oppose constructing power plants near California cities. This has created tie condition of having to transporting many megawatts of power through many miles of tinderbox land in windy conditions.


20 posted on 11/14/2019 4:10:56 AM PST by The_Media_never_lie (Please, oh pretty please let Crazy Uncle Joe Biden be the nominee.)
[ Post Reply | Private Reply | To 19 | View Replies ]