Free Republic
Browse · Search
General/Chat
Topics · Post Article

To: Ernest_at_the_Beach

I guess ‘over-clocking’ is out of the question.. of course, who needs to when this sucker flies as is..


6 posted on 09/06/2012 9:22:01 AM PDT by NormsRevenge (Semper Fi)
[ Post Reply | Private Reply | To 1 | View Replies ]


To: NormsRevenge

I think they might have done an OverClock right from the factory.


10 posted on 09/06/2012 10:37:21 AM PDT by Ernest_at_the_Beach ((The Global Warming Hoax was a Criminal Act....where is Al Gore?))
[ Post Reply | Private Reply | To 6 | View Replies ]

To: NormsRevenge; AngelesCrestHighway; EQAndyBuzz
Trying to find a picture of the incredible chip carrier for the water cooled 3090 -- my last install activity before retiring,...

Did find this from 1995:

Liquid cooling performance for a 3-D multichip module and miniature heat sink

**************************************EXCERPT*****************************************

Abstract

Measured thermal performance is presented for a single phase liquid-cooled module. Tape automated bonded (TAB) thermal test chips and their associated substrates are stacked in a compact, 3-D liquid-tight module. A dielectric liquid, polyalphaolefin (PAO), is forced to flow past the active and inactive sides of TAB chips. At a volumetric flowrate of 0.05 gallons per minute (gpm) and an estimated pressure loss less than 0.5 psi, the measured junction-to-liquid thermal resistance is 2.0 C/W for a 0.50 in.×0.50 in.×0.015 in. thermal test chip. The thermal resistance was also measured for an indirect liquid-cooling approach. PAO was used to cool a miniature sink mounted directly to a 0.50 in.×0.50 in. heat source. The heat source was used to simulate the thermal characteristics of a chip carrier package. The overall dimension of the liquid heat sink is 1.0 in.×1.0 in.×0.28 in. The measured junction-to-liquid thermal resistance is 0.52 C/W for a flowrate of 0.05 gpm, and for an estimated pressure loss less than 1.0 psi. Numerical computational techniques yielded results which were comparable to the measured thermal resistances for both the 3-D module and the miniature heat sink. Enhanced thermal performance gained by introducing micro-encapsulated phase change material (microPCM) to the PAO is estimated for both the 3-D module and the miniature heat sink

12 posted on 09/06/2012 10:51:05 AM PDT by Ernest_at_the_Beach ((The Global Warming Hoax was a Criminal Act....where is Al Gore?))
[ Post Reply | Private Reply | To 6 | View Replies ]

Free Republic
Browse · Search
General/Chat
Topics · Post Article


FreeRepublic, LLC, PO BOX 9771, FRESNO, CA 93794
FreeRepublic.com is powered by software copyright 2000-2008 John Robinson