To: All

http://www.fda.gov/oc/po/firmrecalls/arrowintl04_09.html

Recall — Firm Press Release

FDA posts press releases and other notices of recalls and market withdrawals from the firms involved as a service to consumers, the media, and other interested parties. FDA does not endorse either the product or the company.
Arrow International Announces Worldwide Voluntary Recall of Intra Aortic Balloon Pump (IAB) Catheters

Contact:
Investors: Jake Elguicze 610-948-2836
Media: Julie McDowell 610-948-2829

FOR IMMEDIATE RELEASE — RESEARCH TRIANGLE PARK, NC — April 13, 2009 -— Teleflex Medical announced today that the U.S. Food and Drug Administration (FDA) has classified the voluntary medical device recall initiated on February 2, 2009 by Arrow International’s Cardiac Care Division involving volume connectors for its 30cc, 40cc and 50cc Intra Aortic Balloon Pump (IAB) Catheters as a Class 1 recall. FDA defines Class I recalls as, “a situation in which there is a reasonable probability that the use of or exposure to a violative product will cause serious adverse health consequences or death.”

This recall is being conducted because a fault in the connector of the pump tubing assembly may result in the volume setting on the pump defaulting to 2.5 cc or 5 cc, rather than the appropriate 30, 40, or 50 cc volume. In patients exhibiting moderate to severe myocardial ischemia or low perfusion states, prolonged exposure to the low default volume may fail to decrease ischemia and increase perfusion, leading to organ injury or infarct and may result in patient death. Prolonged exposure to a device which is inflated to less than 2/3 full could also result in thrombus formation on the IAB and possible subsequent systemic or cerebral thromboembolism.

Instructions contained in the operator’s manual fully describe the necessary warnings and precautions that will identify the issue. The recall notice restates these instructions and references the sections in the owner’s manual. If these instructions are followed, the issue for which the product was recalled can be discovered immediately, and the product can be removed and replaced.

Arrow International notified both domestic and foreign hospitals and distributors via an Urgent Medical Device recall letter dated February 2, 2009 that the company had become aware that the blue connector for the 40cc IAB was not properly recognized by the Arrow Intra-Aortic Balloon Pump (IABP) system. This recall involved the retrieval of unused product, issuance of mitigation instructions for patients and/or facilities in critical need, and the replacement of pump tubing assemblies.

At this time, there have been 25 complaints of this issue. There have been no reports of patient injury as a result of this issue. Approx. 423 lots are affected by this recall for a total 45,211 units.

PRODUCTS AFFECTED: 30/40/50 CC IAB Catheters:

PRODUCT CODES: IAB-04830-U, IAB-04840-U, IAB-05830-LWS, IAB05830-U, IAB-05840-U, IAB-05840-LWS, IAB06830-U, IAB06840-U, IAB-S730C, IAB-S840C, IAB-R950-U, IAK-02692, IAK-02693, and IAK-02691.

A list of products and lot numbers affected by this recall as well as the original recall notice can be found at Arrow’s website:

http://www.arrowintl.com/iab_recall.asp

Consumers with questions may contact the company at 1-800-523-8446; 8am to 8pm, ET, Monday through Friday, for international calls 001-919-361-4062; 8am to 5pm, ET, Monday through Friday.

Any adverse reactions experienced with the use of this product, and/or quality problems can also be reported to the FDA’s MedWatch Program by phone at 1-800-FDA-1088, by Fax at 1-800-FDA-0178, by mail at MedWatch, HF-2, FDA, 5600 Fishers Lane, Rockville, MD 20852-9787, or on the MedWatch website at www.fda.gov/medwatch

#


6,504 posted on 04/14/2009 2:57:36 PM PDT by nw_arizona_granny ( http://www.freerepublic.com/focus/chat/2181392/posts?page=1 [Survival,food,garden,crafts,and more)
[ Post Reply | Private Reply | To 6469 | View Replies ]

To: All

Plain Language Insulin Guide

AHRQ has released plain-language guides for consumers and clinicians comparing the efficacy, effectiveness, and side effects of newer premixed insulin analogues to conventional insulin (human insulin) and other preparations used to control Type 2 diabetes.

The consumer guide, called Premixed Insulin for Type 2 Diabetes: A Guide for Adults, is a primer on diabetes, diabetes testing, and treatments. It is available at: http://effectivehealthcare.ahrq.gov/healthInfo.cfm?infotype=sg&ProcessID=18&DocID=125

The clinician guide, called Premixed Insulin Analogues: A Comparison with Other Treatments for Type 2 Diabetes, includes additional information, such as a confidence scale that rates available evidence. It is available at: http://effectivehealthcare.ahrq.gov/healthInfo.cfm?infotype=sg&DocID=124&ProcessID=18

Copies of the guides are available by sending an e-mail to ahrqpubs@ahrq.hhs.gov.


6,506 posted on 04/14/2009 3:01:58 PM PDT by nw_arizona_granny ( http://www.freerepublic.com/focus/chat/2181392/posts?page=1 [Survival,food,garden,crafts,and more)
[ Post Reply | Private Reply | To 6469 | View Replies ]

Free Republic
Browse · Search
General/Chat
Topics · Post Article


FreeRepublic, LLC, PO BOX 9771, FRESNO, CA 93794
FreeRepublic.com is powered by software copyright 2000-2008 John Robinson