Free Republic
Browse · Search
News/Activism
Topics · Post Article

To: Ramius
But it wasn't built to the design. And the as-built never really got any "engineering" at all. That's why it fell.

They failed to comply with the Structural Engineer's design.
The rods used to hold up the suspended sections were attached in a manner that put the load on one threaded connection at the lowest level, instead of the three that the engineer required.
The threaded rod pulled through the nut and washer...

1,540 posted on 08/01/2007 8:54:37 PM PDT by concretebob (I'm NOT pro-war, I'm ANTI - TERRORIST)
[ Post Reply | Private Reply | To 1525 | View Replies ]


To: concretebob
The threaded rod pulled through the nut and washer...

No, the threaded rod and the nut and washer pulled though the welded joint in the box-welded beam.

1,576 posted on 08/01/2007 9:13:17 PM PDT by Ramius (Personally, I give us... one chance in three. More tea?)
[ Post Reply | Private Reply | To 1540 | View Replies ]

Free Republic
Browse · Search
News/Activism
Topics · Post Article


FreeRepublic, LLC, PO BOX 9771, FRESNO, CA 93794
FreeRepublic.com is powered by software copyright 2000-2008 John Robinson