Incorrect. The fission product 131I has a half-life of eight days. You're not taking credit for decay. You want to block uptake. Once the thyroid uptake is saturated, the main effect is biological clearing time. You don't worry about radiological half-life so much if you're not taking in the material an such a way that it accumulates.