Running 5 KW through a receptacle fed by #12(if you’re lucky, some houses are wired with #14) is NOT advisable.

That would be because 5KW is about 40A single phase at 120V, and the wire in the receptacle is rated from for a max of 20A.

As the load goes up past 20A, the wire WILL heat up to the point where it will start a fire or more likely just burn through and need to be replaced.

Of course if your total load is below 20A it would be OK.